22nd International Conference on Harmonics and Quality of Power
August 31 – September 3, 2026 (+ excursion Sept 4) · Penck Hotel Dresden, Ostra-Allee 33, 01067 Dresden, Germany
Host: TU Dresden, Institute of Electrical Power Systems & High Voltage Engineering · General Chair: Jan Meyer
🔴 Today — Monday 31 Aug, Day 1. Six decisions, in the order they expire.
Are you in Dresden, Germany? Expires: immediately. This is not in Estonia. Everything below assumes you're here or can be here by 13:00 CEST. Nothing else on this list matters until this one is answered.
Registration — pay the tutorial add-on. Desk opens 13:00, Lobby. On-site rate is €900 regular / €480 student — but IEEE membership knocks it down (Member €840, PES Member €780; student equivalents €450 / €420). Tutorials are +€75, or +€25 if you are registering as a student. You can still do the whole thing online at ichqp.ticket-web.site/2026 rather than queuing. The form asks which tutorials you want — decide before you fill it in.Decision: pay the €75. It buys the only four sessions all week that are built to teach a newcomer rather than report a result. Best-value line on the invoice, and there is no way to buy it back on Tuesday.
Excursions — call today, not tomorrow. Both were meant to be booked at registration, first-come-first-served. Meißen (Thu 3 Sep) is included in your fee but still needs a reservation. Saxon Switzerland (Fri 4 Sep) is capped and costs €135. Decision: ring +49 1551 1288184 (07:00–22:00 CEST) or email registration@ichqp2026.org before lunch — every hour you wait, the caps fill.
14:00 tutorial — which room. Two live options plus one trap.
→ Pick: CPC power theory (Czarnecki, Room D). It puts you inside the field's oldest live argument — that "power factor" and "reactive power" stop being well-defined the moment the waveform isn't a sine. Hold it loosely: it's his framework, a minority position, not consensus.
→ Close second: CIGRE TB976 voltage-measurement frequency response (Sperling, Room A). Narrower, but it's the only tutorial about whether your measurement is even true. Take this one instead if you expect to care about instruments and the vendor market more than about theory.
→ Trap: the 3-hour hosting-capacity tutorial (Room B) eats both your afternoon slots for one narrow topic. Skip.
16:00 tutorial — which room.Decision: EV Charging PQ & metering verification (van den Brom, Room D). Most PM-shaped 90 minutes of the week: when a 350 kW charger bills a customer, who certifies the meter, with what kit? That's a market being defined in public. The alternative is geomagnetic storms with Math Bollen, who wrote the textbooks — better story, less use. You don't have to trade one for the other: Bollen co-authors three Wednesday posters (#23, #31, #124), so take van den Brom now and corner him in the poster hall. Rooms differ, so mixing Track 2 at 14:00 with Track 1 at 16:00 is physically fine — one fee covers both — but name them on the form.
Welcome Reception, 18:30 doors / 19:00, Nymphenbad at the Zwinger. Free, sponsored by Reinhausen, open-air in a Baroque courtyard. Decision: go, and go early. Nobody has formed cliques yet — this is the highest-yield networking hour of the entire week, and it is strictly downhill from here. 750 m walk from the hotel.
Everything above, plus every other fork in the week, is in the interactive planner — with the running cost.
Not a decision, but do it today: the exhibition floor and the Job Wall are on the ground floor with no scheduled slot, which is why everyone skips them. Five scripted questions per booth are in section 4 — start tonight at the reception if the floor is already up.
1 · What ICHQP actually is — 8 facts
Fact 01It is the only IEEE Power & Energy Society conference dedicated exclusively to Power Quality. Everything else in PES treats PQ as a sub-track; here it's the whole event.
Fact 0240+ years old, 22nd edition. It runs roughly every 18 months and rotates continents. Dresden 2026 is hosted by TU Dresden's Chair of Energy Systems.
Fact 03It's small and dense, not a mega-conference. ~150 accepted papers across 24 technical sessions plus one poster session — at most 4 parallel tracks, so you can genuinely see a meaningful fraction of it.
Fact 04It's where power-quality standards get argued into shape. The keynote list alone includes the past chair of IEEE 519, the chair of IEC TC77/SC77A, and the convenor of IEC SC77A WG9.
Fact 05New in 2026: the "Art of Power Quality" contest. Ten jury-selected images from real PQ research hang in the Kunsthalle; every attendee gets one vote via the conference app, winner announced at the gala dinner and takes home a PQ-Box ONE.
Fact 06Two named awards, both decided here: the Constantin Budeanu Best Paper Award (all papers auto-entered) and the Alex Emanuel Best Student Paper Award. Announced at the gala dinner on the boat.
Fact 07Genuinely global. The 2026 papers and panels bring in grid operators and labs from Germany, Netherlands, UK, France, Ireland, Czechia, Australia, China, Japan, Taiwan, Brazil, Mexico, South Africa, New Zealand and the USA — plus two papers from CERN's accelerator grid.
Fact 08The 2026 obsessions are clear from the session titles: grid-forming inverters, supraharmonics (2–150 kHz), DC power quality, EV-charging & data-centre emissions, and geomagnetically induced currents. If you want the field's current frontier in one week, that's it.
2 · Who comes, and what gets decided
Who's in the room
Group
Who, specifically
What they want from you
Transmission & distribution operators
TransnetBW, TenneT, National Grid (UK), EDF, NTCSA (ex-Eskom, South Africa), State Grid China, Czech TSO, EirGrid (Irish allocation paper)
Field evidence. They present real incidents and want to know if you've seen the same thing.
Instrument & test manufacturers
OMICRON (platinum), A. Eberle, iba AG, Powerside, NEO Messtechnik, Camille Bauer/Gossen Metrawatt, Spitzenberger & Spies, CT LAB, McEachern Labs
Requirements. The exhibition on the ground floor is where the "can your box do X" conversations happen.
National metrology institutes
METAS (CH), VSL (NL), NPL (UK), RISE (SE), CERN
Traceability arguments — they're writing the measurement methods everyone else will have to comply with.
Academics & PhD students
TU Dresden, Luleå, Wollongong, KU Leuven, Auburn, Campinas, Basque Country, Chung Cheng, Canterbury (NZ)
Collaborators and data. Most of the poster session is students.
Software & consultancy
DIgSILENT (PowerFactory), EPRI, VandA Engineering, Electric Power Consulting (AU), GRIDSIDE, PQ Professionals, Reinhausen, Condensator Dominit
Modelling assumptions and, frankly, business.
What decisions actually get made
ICHQP is not a voting body — it's the pre-negotiation room for decisions that later become formal standards. Concretely, in 2026:
Emission limits. Mark Halpin convenes the CIGRE working group revising the IEC Technical Reports on emission limits for harmonics, voltage fluctuations and unbalance (IEC/TR 61000-3-6 & friends). Panel 1 and TS 10 are effectively public consultation on that.
Measurement methods. Guglielmo Frigo convenes IEC SC77A WG9 ("Power Quality Measurement Methods") and is pushing reference methods for DC power quality and network-impedance measurement — Panel 4 is the shortlist of gaps.
What counts as "power" at all. TS 20 is an open fight over power definitions under nonsinusoidal conditions, including a critique of the brand-new IEEE Std 1459-2025 and Czarnecki arguing Fryze's approach failed. Genuinely contested territory.
Grid-forming converter requirements. TS 5 + Panel 3 feed the joint IEEE/CIGRE task force revising IEEE TR77 stability definitions for converter-dominated grids (Marco Lindner is a key member).
Supraharmonic / 2–150 kHz standardisation. Repeatedly flagged as the biggest open hole — no standardised impedance measurement above 9 kHz yet.
The two paper awards and the art contest — decided by jury and by attendee vote respectively, both announced at the gala dinner.
Hiring. There's a literal Job Wall on the ground floor next to the exhibition.
3 · Build your week — interactive planner
Every genuine fork in the conference, in one place, with the money attached. Pick an option in each slot. The bar at the bottom follows you down the page with the running cost and — the bit that actually matters — what each fee is buying you. Choices save in this browser, so you can come back to it between sessions.
Green = my pick · amber = a real alternative, not a consolation prize · grey = skip. Where two options are genuinely close I've said so rather than pretending there's one right answer.
€0
4 · The schedule, with picks
How I picked — v2, re-coloured for learning the field. You said: learn as much power quality as possible, mainly as a PM, but engineer-first. That is a different optimisation from "attend your specialty," and it changes the picks. I now weight:
Teaching sessions over result sessions. Tutorials and panels explain the shape of a problem. A 15-minute paper assumes you already know the shape. Monday's tutorials went from "optional extra" to the highest-value block of the week.
Breadth of phenomenon over depth of method. A session with five different real networks teaches you more than five refinements of one algorithm. Numerical-method sessions stay grey — not because they're bad, but because they're unreadable without the field first.
Effects, not just causes. Most engineers learn PQ from the emission side (what distorts the grid). The half that PMs actually need is the immunity side — what breaks, at what threshold, and who eats the cost. TS 15 moved to green for exactly this.
Rooms where you can ask questions. Poster session and the exhibition floor beat any lecture for questions-answered-per-hour. Both are now first-class agenda items.
Where two parallel sessions were genuinely close, I've said so rather than pretending there's one right answer.
Attend go hereOptional good, but only if it's your areaSkip low return unless it's literally your job
Rooms: Kunsthalle (main hall) · A · B · D (Thu only) · Y · C = Speaker Ready Room · Z + restaurant = lunch. All times CEST.
Standing item · every coffee break (10:30–11:00, 15:30–16:00) and lunch · ground floorThe exhibition floor — treat it as competitive research, not a snack runDo this daily
There is no scheduled exhibition slot, which is exactly why people skip it. Don't. Roughly a dozen vendors are in the building — OMICRON, A. Eberle, Powerside, iba AG, NEO Messtechnik, Camille Bauer/Gossen Metrawatt, Spitzenberger & Spies, CT LAB, DIgSILENT, McEachern Labs — and over four days of breaks you can get a full product-landscape download for free. As a PM this is the densest commercial intelligence available anywhere in power quality.
Ask every booth the same five questions so the answers are comparable, and write them down the same day:
"Who's your typical customer, and what did they buy this to stop happening?" — gets you the real use case, not the datasheet.
"What's the bandwidth, and what happens above 9 kHz?" — the honest answers separate the serious instruments from the rest. This is the supraharmonic gap; watch who squirms.
"How does the data get out — file format, protocol, API?" — PQ is drowning in proprietary export formats. PQDIF (IEEE 1159.3) and COMTRADE exist; ask who actually supports them.
"What do your customers ask for that you can't do yet?" — the roadmap question. Sales engineers answer it; marketing people deflect it.
"Who do you lose deals to, and why?" — asked friendly and late in the conversation, this works more often than you'd think.
Also on the ground floor: the Job Wall. Worth a two-minute read even with zero interest in moving — job ads are the least filtered statement any organisation makes about what it's actually struggling to do. A wall of "we need someone who can X" is a free list of unmet needs in the field.
Monday, August 31 — Tutorials + Welcome Reception
⏰ Arrive 13:00. Registration desk (Lobby) opens 13:00 and tutorials start at 14:00 — you need a badge before you can enter anything.
📄 The tutorial slides are published. TU Dresden has released all four tutorial decks (eight PDFs, ~47 MB total) on Datashare: the full folder is here. Each tutorial below now links straight to its own deck, including the two you did not sit in — which is the cheap way to get the other track back.
A note on the green badges below: they are the recommendations I made before the conference, not a record of what was attended. Monday's picks here are CPC (14:00) and EV charging (16:00); if the afternoon went Track 1 instead — Sperling then the GIC session — say so and I will re-mark it as an attendance record rather than a plan.
Monday is now your most important day. If your goal is to learn the field rather than track your specialty, the tutorials are the only sessions all week that are designed to teach. Everything from Tuesday on assumes you already speak the language. The +€75 tutorial fee is the best-value line item on the invoice — pay it. Do not treat Monday as an optional warm-up you can skip in favour of a later flight.
14:00 – 15:30 · Tutorial Track 2 · Room DDecomposition into Currents' Physical Components (CPC) — Leszek S. Czarnecki, Louisiana State UniversityAttend
Power theory for nonsinusoidal and unbalanced circuits, taught by the man who built the framework. The reason it's worth 90 minutes to a newcomer: it forces you to confront the fact that "reactive power" and "power factor" are not well-defined once the waveform stops being a sine wave — and the whole field disagrees about the replacement. Understanding why that argument exists is more load-bearing than knowing who wins it.
One honest caveat: CPC is Czarnecki's own framework and it is a minority position, not the consensus. You are getting one strongly-held view of a contested area. That's fine — but hold it loosely, and go to TS 20 on Thursday to hear it attacked. The pair is the real education.
Runner-up: Track 1 — CIGRE TB976, frequency response of voltage measurement systems (Erik Sperling, Room A). Narrow, but it's the one tutorial about how you know your measurement is true — relevant if you end up caring about the instrument market. Sperling also co-authors poster 75 on broadband voltage measurement calibration.
16:00 – 17:30 · Tutorial Track 2 · Room DEV Charging Systems: Power Quality, Metering Accuracy, and On-Site Verification — Helko van den Brom, VSLAttend
The most directly applicable 90 minutes of the day, and the most PM-shaped session all week. AC/DC test benches up to 44 kW / 350 kW, load emulators, and the new on-site verification procedures for legal metrology. The subtext is a product question: when a 350 kW charger bills a customer, who certifies that the meter is right, and with what equipment? That's an entire market being defined in public. Van den Brom also sits on Panel 4 on Tuesday, so you get continuity.
The fun alternative: Track 1 — Impact of Geomagnetically Induced Currents on Power Quality (Room A), with Math Bollen — who wrote the textbooks most of this room learned from, so meeting him is worth something on its own. Solar storms bending transformer cores into saturation. Best story of the day; least likely to be useful on Monday morning back home.
You don't have to choose to meet Bollen: he's a co-author on three Wednesday posters (#23 DC-side power quality, #31 hosting capacity, #124 harmonic impedance from a TSO's view). Catch him in the poster hall instead and take van den Brom here.
Officially settled: the fee "includes either a 3 hour tutorial or up to 2 consecutive 1.5 hour tutorials" — so one €75 covers both afternoon slots and you may mix tracks freely. But you must name the tutorials you want in the registration form; it is not open-door seating.
14:00 – 17:30 · Tutorial Track 3 · Room BStochasticity of Harmonic Impedances and Injections for Hosting Capacity (3h, Parts A+B)Skip
Still a skip, and more so under the new goal. It costs your entire afternoon — both tutorial slots — for one narrow topic, it's heavy uncertainty-quantification maths, and it's largely a showcase for the EU HARMONIC project. Breadth is the whole point of your week; this is the single deepest, narrowest option on offer. (Worth knowing the concept though: hosting capacity = how much new distributed generation or load a feeder can absorb before some limit — usually voltage or harmonic distortion — is breached. It's the number utilities argue about every time someone wants to connect solar or a charger bank.)
Doors 18:30 · starts 19:00 · ends 22:00. Free (sponsored by Reinhausen), open-air cocktail reception in the Baroque courtyard of the Zwinger, Theaterplatz 1. Attendance requires having ticked it in the registration form — do it at checkout if you are registering today. This is the single best networking hour of the week — everyone is fresh and nobody has formed cliques yet. 750 m / ~10 min walk from the hotel, or tram 11 → Postplatz, change to 3/4/9 → Theaterplatz.
Tuesday, September 1 — Opening, all four keynotes, panels
⏰ Arrive 08:00–08:10. This is the day to be early: desk opens 07:30, Opening Ceremony is 08:30 sharp in the Kunsthalle, and all four keynotes run back-to-back 09:00–10:30. Turning up at 09:15 means missing a keynote you cannot catch later.
08:30 – 09:00 · KunsthalleOpening CeremonyAttend
Short, and it's where the organisers flag programme changes, app instructions and the art contest. Also, the room fills — being there means you get a good seat for the keynotes.
Non-negotiable. Four people who between them chair IEEE 519, IEC TC77/SC77A, and formerly CIGRE SC C4. Full profiles in section 5 below.
11:00 – 12:30 · Panel 2 · Room AOpportunities and Challenges in Large-Scale Power Quality Data Analysis — Chair: Gary ChangAttend
The most transferable panel of the four. You get State Grid China's monitoring findings, TenneT's transmission-grid lessons, gigawatt offshore-wind root-cause analysis (iba), and an Australian statistical-compliance view — i.e. what actually happens when you have too much PQ data.
Upgraded in v2 — parallel option, now an equal pick:Attend Panel 1 — Field Experiences in Managing Compliance with Emission Limits (Chair Herwig Renner, Kunsthalle). If you want to understand how the rules actually bite — the moment a real project is told "no, you can't connect that" — this is the better of the two. Resonance damping, wind-turbine interharmonics, South African renewables connection experience.
Honest split: Panel 1 teaches you the regulatory mechanics of the field; Panel 2 teaches you its data problem. For learning the field cold, Panel 1 is arguably the more foundational of the two — Panel 2 makes more sense once you know what the data is for. Pick Panel 1 if that framing lands.
14:00 – 15:30 · Panel 3 · KunsthallePower Quality Challenges in AC and DC Networks with a High Share of Power Electronics — Chair: Xavier Yang, EDFAttend
The conference's central theme, in the main hall, with DIgSILENT on simulation-based resonance stability, NPL on grid-forming metrology, and Reinhausen on "control algorithms vs grid physics". If you attend one panel all week, this is it.
Parallel option:Optional Panel 4 — Advanced Metrology for New Power Quality Applications (Chair Guglielmo Frigo, Room A). Take it instead if you care about measurement hardware: switching-transient monitoring, LED flickermeters, DC PQ measurement gaps, impedance measurement up to 150 kHz.
16:00 – 17:30 · TS 2 · Room AEmission of Electric Vehicle Charging and Data Centers — Chair: Paola VerdeAttend
Five very applied papers: V2G emission limits from high-frequency impedance measurements, field-measurement-based probabilistic EV emission modelling, LV residential charger impact, and skin-effect losses in data-centre distribution. The two loads everyone is worried about, in one session.
Parallel:Optional TS 1 — Power Quality in DC grids (Kunsthalle): 700 V industrial DC, railway traction, 325 V DC home lab, supraharmonic testbed. Excellent if DC is your direction. Skip TS 3 (forecasting) and TS 4 (impedance measurement technique) unless that's literally your research.
18:30 doors / 19:00 – 22:00 · Felix Restaurant, Kleine Brüdergasse 1–5Women in Power Quality receptionN/A
Female participants only (sponsored by ABB), pre-registration required. Noted for completeness — your Tuesday evening is otherwise free. 800 m / ~12 min walk from the hotel; Dresden Altstadt is worth an evening on foot.
Wednesday, September 2 — Technical sessions, posters, gala dinner
⏰ Arrive 08:40. Desk opens 08:30, sessions start 09:00. Two hard deadlines today: vote in the PQ Art Contest before 17:30 (app → Power Quality Art Contest, one vote each), and leave the venue by 18:05 for the gala boat.
09:00 – 10:30 · TS 5 · KunsthalleRequirements and Performance of Grid-Forming Inverters — Chair: Roberto LangellaAttend
The hottest topic in the field right now, in the main hall. Functional specs review (Lodetti/NPL), standards-to-testbed translation, black-box harmonic impedance identification via single-tone injection, and a grid-following vs grid-forming head-to-head on a commercial inverter.
Parallel:Optional TS 6 — Connection Studies and Compliance Assessment (Room A) if you do connection studies. Skip TS 7 (simulation techniques) and TS 8 (PMU / harmonic phasor estimation) — narrow and method-heavy.
11:00 – 12:30 · TS 11 · Room BDistortion in Low Voltage Networks and Neutral Conductor Loading — Chair: Pasquale De FalcoAttend
The most varied and tangible session of the morning: South African LV supraharmonics, 400 V industrial grids and frequency converters, the fifth harmonic in Japanese downtown networks, triplen harmonics at CERN, and stray currents at a traction converter station. Five completely different real networks.
Parallel:Optional TS 9 — Characterization and Modelling of Inverter-Based Resources (Kunsthalle) and Optional TS 10 — Harmonic Emission Limits and Allocation Methods (Room A). TS 10 is the one to pick if you ever have to allocate limits — it has the England & Wales, Irish and IEC/TR 61000-3-6 headroom papers. Skip TS 12.
14:00 – 15:30 · KunsthallePoster Session (pitches 14:00–14:40, then open floor)Attend
The single highest-value 90 minutes of your week, and it isn't close. ~40 papers that aren't in the oral programme, each with a 1-minute pitch first so you can triage, then open floor. A poster author will explain their entire problem from first principles to anyone who asks — a keynote speaker will not. For someone deliberately learning a field, that asymmetry is everything.
How to work it: during the 14:00–14:40 pitches, mark 8–10 posters. Then walk them in order and ask each author the same two questions — "what were you actually measuring, and what surprised you?" and "what would have made this easier?" The second question is your product research; people answer it honestly at posters and defensively at booths.
Specific stops: #23 Challenges with power quality at the DC side and #124 Harmonic impedance of a network: a TSO perspective (both Bollen) · #110 Two-location voltage measurement for 2–150 kHz propagation (Lodetti/NPL — the supraharmonic gap, measured) · #19 PQ disturbances and PMUs at CERN · #7 Implementation of EN 50160 by the Czech TSO — that last one is the clearest "how does a real operator actually apply the standard" artefact in the building.
Posters stay up all Wednesday including lunch and coffee breaks, and come down 17:30–18:00.
by 17:30 · conference appVote in the Power Quality Art ContestDo it
Ten images in the Kunsthalle, one vote per attendee, voting closes 17:30 Wednesday, winner announced at the gala. Takes 90 seconds and it's the first year they've run it. App: ichqp2026.lineupr.com/ichqp-2026 (register with your ticket email).
Promoted to the pick in v2 — this is the session that teaches you the half of power quality most engineers skip. Nearly everything else at ICHQP is the emission side: what injects distortion into the grid. This session is the immunity side: what actually breaks, at what threshold, and therefore what anyone is willing to pay to prevent. That's the half a product manager needs, and it's the half that connects PQ to money.
Five concrete papers: household appliances under sustained off-nominal supply voltage (two papers, Wollongong) · EV charger performance under distorted supply · LED lamps flickering from wideband interharmonics thrown off by active front-end drives · and a new method for scoring equipment sensitivity to voltage-dip sequences rather than single dips. All measured on real hardware.
Very close parallel — take it if incident forensics appeal more:Attend TS 13 — Sub-synchronous Oscillations and Harmonic Stability (Kunsthalle, Chair Carlos Duque). Contains the Dutch 3.5 Hz case, a real named oscillation event in a converter-heavy grid, presented by the people who lived through it. This is the most dramatic session of the week and the main hall will be full. Genuine coin flip: TS 15 teaches you the field's economics, TS 13 teaches you its scariest failure mode.Skip TS 14 (harmonic modelling/aggregation) and TS 16 (measurement reproducibility) — both method-heavy.
Free (sponsored by Condensator Dominit), dinner buffet with music, and both paper awards plus the art contest winner are announced here. Note: 1.2 km / ~20 min walk from the venue, and the departure platform is only announced on the day — check the information desk. Leave by 18:05. You cannot rejoin a boat.
Thursday, September 3 — Final sessions, closing, Meißen excursion
⏰ Arrive 08:45. Desk open 08:30–13:00 only. Closing ceremony 12:15 in Room A, lunch 12:30 in Room Z, and the Meißen bus boards 13:30 / departs 14:00 — that transition is tight, don't linger over lunch.
09:00 – 10:30 · TS 17 · Room AHarmonic Analysis and Mitigation Case Studies — Chair: Aurora Gil-de-CastroAttend
The best "actual engineering" session of the week — every paper is a real installation: resonance in an LED-lit seed growth chamber, an industrial green-ammonia plant on large electrolyzers, an active power filter in a wastewater treatment plant, a Swedish charging site, and EV integration in distribution. Problems, measurements, fixes.
The spicy alternative:Optional TS 20 — Power Metrics and Definitions under Nonsinusoidal Conditions (Room D). Czarnecki on "Why Fryze's Approach to Developing Power Theory has Failed", a critical teardown of the brand-new IEEE Std 1459-2025, and an argument that PQ billing should be based on currents not powers. Pure argument, no case studies — go if you enjoyed the Monday CPC tutorial. Optional TS 19 (voltage sags) if sags are your problem; Skip TS 18.
11:00 – 12:05 · TS 22 · Room BHarmonic Emission of Other Sources — Chair: Johanna MyrzikAttend
Four genuinely unusual failure modes: railway signalling interference from a DC traction rectifier open-arm fault, quantified harmonic losses in MV cables, a large heat pump's real distortion footprint, and GIC-driven harmonic anomalies causing protection mal-trips in the South Atlantic Anomaly. The "things nobody warned you about" session.
Parallel:Optional TS 24 — Platforms and Methods for Large Data Analysis (Room D) if you liked Panel 2. Optional TS 21 (impedance campaigns) has the strong Basque/Luleå supraharmonic impedance work. Skip TS 23.
12:15 – 12:30 · Room AClosing CeremonyOptional
15 minutes, mostly thanks and the announcement of the next host city. Worth staying for the next-venue reveal — and you're in the building anyway if you're taking the Meißen bus.
13:30 boarding / 14:00 departure / ~19:00 returnExcursion 1 — Meißen: Porcelain Manufactory or Historic City Centre + AlbrechtsburgAttend
Included in the conference fee — you only need to have reserved a place. Half day, and it's the excursion with the best cost/benefit since it's free and everyone else is on it (i.e. five more hours of networking). Choose the Historic City Centre + Albrechtsburg option if you want Germany's oldest late-Gothic castle and Elbe views; choose the Manufactory if you want to watch artisans work. Cobblestones and stairs either way.
Friday, September 4 — Saxon Switzerland (optional, paid)
⏰ Bus boards 08:30, departs 09:00, returns ~18:00. Nothing else happens on Friday — the conference proper ended Thursday.
08:30 – 18:00 · full dayExcursion 2 — Königstein Fortress + Bastei Bridge, Saxon Switzerland National ParkAttend if you can still get a seat
One of the largest hilltop fortresses in Europe, lunch included there, then the Bastei Bridge over the Elbe Sandstone Mountains with afternoon coffee and snacks. Weather permitting there's an optional ~2 h hike with ~250 m of ascent, narrow passages and a lot of stairs — bring proper shoes. Costs €135 at the current rate, capacity is limited, first-come-first-served, and it must be booked in advance. Not accessible for mobility impairments.
If it's sold out: Saxon Switzerland is easy to do independently — S-Bahn S1 from Dresden to Kurort Rathen (~40 min), ferry across, walk up to the Bastei. Cheaper, and you set your own pace. You lose the Königstein guided visit and the bus.
5 · The speakers — four facts each
Keynotes (Tuesday 09:00–10:30, Kunsthalle)
S. Mark Halpin
Keynote · Fellow, IEEE
Where he is: Professor, Department of Electrical and Computer Engineering, Auburn University, USA.
What he teaches/researches: power systems, control systems and network analysis; research in power system dynamic performance and power quality.
Standards weight: former Chair of IEEE 519 (the harmonic limits standard most of the world cites), current Chair of IEC TC77/SC77A — responsible for standardisation of all low-frequency conducted disturbances in power systems.
Contribution to the community: convenes the CIGRE working group revising the IEC Technical Reports on emission limits for harmonics, voltage fluctuations and unbalance. If your grid code has a harmonic limit in it, his committees shaped it.
Sarah Rönnberg
Keynote · Senior Member, IEEE
Where she is: Professor and Head of the Electric Power Engineering group at Luleå University of Technology, Sweden (head since 2025).
Education: PhD in Electric Power Engineering from Luleå, 2013 — same university she now leads the group at.
Research focus: distribution grids and power quality, with particular attention to harmonics and supraharmonics in systems with a high share of power-electronic equipment. Effectively one of the people who put supraharmonics (2–150 kHz) on the map as a discipline.
Contribution: bridges academia and industry, supervises heavily — she's a co-author on several 2026 papers here (supraharmonic impedance campaigns, traction stray currents, GIC protection mal-trips), which tells you her group is doing a lot of the field measurement in this space.
Zia Emin
Keynote · Technical Executive, EPRI
Career shape: 14 years at National Grid (UK transmission owner/operator), then 12 years in consultancy as Chief Power System Engineer and Technical Director; since 2023 at EPRI as Technical Executive. The rare keynote who has been operator, consultant and researcher.
Where he's from / credentials:United Kingdom — Fellow of the IET, Senior Member of IEEE, registered European Engineer and Chartered Engineer.
Technical depth: steady-state, frequency-domain and time-domain power system modelling; harmonic performance specification for HVDC converter stations, FACTS and renewable connections.
Contribution:Chaired CIGRE Study Committee C4 (2016–2022) and its Strategic Advisory Group; Distinguished and Honorary Member of CIGRE. Currently reviewing harmonics-management policy for major TSOs — i.e. he decides what "acceptable" looks like at national scale.
Marco Lindner
Keynote · Lead Engineer, TransnetBW
Where he is: lead engineer for power system stability at TransnetBW, one of the four German transmission system operators — the operator's-eye view on this keynote panel.
Focus: sub-/super-synchronous and harmonic stability; power-electronics-coupled systems (HVDC, storage, FACTS) and their interactions across a wide frequency range.
Hands-on background: four years across specification, engineering, offline and real-time simulation studies, verification measurements and commissioning of power-electronics-based systems. He has actually commissioned the things he models.
Contribution: co-convenor of the German 4TSO working group on power quality, and a key member of the joint IEEE/CIGRE task force reassessing power system stability definitions for converter-dominated grids (revising IEEE TR77).
Panel chairs
Herwig Renner
Chair, Panel 1 — Field Experiences in Managing Compliance with Emission Limits (Tue 11:00, Kunsthalle)
Education: PhD 1995 at Graz University of Technology, Austria — and still there.
Position: Associate Professor at the Institute of Electrical Power Systems, Graz.
Research: power system control and stability, plus power quality with a specific focus on industrial disturbers — the big ugly loads.
Contribution: member of the CIRED Technical Committee and of several CIGRE working groups on power quality. Also a co-author here on a GIC transformer-magnetising-current paper.
Gary W. Chang
Chair, Panel 2 — Large-Scale Power Quality Data Analysis (Tue 11:00, Room A)
Education: PhD from the University of Texas at Austin, 1994.
Where he is:National Chung Cheng University, Taiwan.
IEEE service: Chair of the IEEE PES Power Quality Subcommittee (2016–17) and Chair of the IEEE PES Transmission & Distribution Committee (2019–20).
Contribution: Senior Editor of IEEE Transactions on Power Delivery and Associate Editor of IEEE Power Engineering Letters — he is one of the gatekeepers for where this field's work gets published. Also has two poster papers here on TFA-based PQ assessment and IEEE 1459-based active filter control.
Xavier Yang
Chair, Panel 3 — PQ Challenges in AC/DC Networks with High Power Electronics (Tue 14:00, Kunsthalle)
Where he is:Électricité de France (EDF) R&D Institute, France — for more than 30 years.
Research: power grid modelling, power electronics applications, on-site power quality mitigation, and the development of simulation tools.
Standards roles: expert and working group convener in IEC SC77A, IEC SC8B and CIGRE.
Contribution: the bridge between a large national utility's operational reality and international standardisation. He's also co-author on the LVDC 0–9 kHz measurement-method proposal in TS 1.
Guglielmo Frigo
Chair, Panel 4 — Advanced Metrology for New PQ Applications (Tue 14:00, Room A)
Where he is: Senior Scientist at METAS, the Swiss Federal Institute of Metrology, Bern, Switzerland.
Key role: since October 2025, convenor of IEC SC77A WG9, "Power Quality Measurement Methods" — the group that decides how PQ is allowed to be measured.
Current agenda: establishing reference methods for DC power quality and network impedance measurement, which currently have no rigorous standard.
Contribution: pushing a metrological framework for harmonic and supraharmonic measurement that satisfies both the EMC community and the power-systems community — historically two camps that measure the same thing differently. Also co-authors two papers here (harmonic phasor field measurements; DC ripple Hall transducer errors).
Panelists worth seeking out
Name
Org / country
Talking about
When
Math Bollen
Luleå, Sweden
Geomagnetically induced currents; also a hosting-capacity paper (TS 18) and DC-side PQ poster
Mon 16:00 tutorial
Helko van den Brom
VSL (NL metrology institute)
EV charging metrology (tutorial) + gaps in DC PQ measurement (Panel 4)
Mon 16:00 + Tue 14:00
Brandon Peterson
NTCSA (ex-Eskom), South Africa
Connecting large renewable plants to a stressed grid
Tue 11:00 Panel 1
Jeroen van Waes
TenneT TSO, Netherlands
What a decade of transmission PQ measurement actually taught them
Tue 11:00 Panel 2
Ulrich Lettau
iba AG, Germany
Harmonic root-cause analysis in gigawatt offshore wind farms
Tue 11:00 Panel 2
Stefano Lodetti
NPL, United Kingdom
Metrology for grid-forming converters (EU GridForm project)
Tue 14:00 Panel 3 + chairs TS 24
Neville Watson
Univ. of Canterbury, NZ
Future Architecture of the Network project; chairs TS 15
Tue 14:00 Panel 3
Leoš Kukačka
TU Liberec, Czechia
Why the standard flickermeter is wrong for LED lamps
Tue 14:00 Panel 4
Alexander Gallarreta
Univ. of the Basque Country, Spain
The missing standard for impedance measurement up to 150 kHz
Tue 14:00 Panel 4
Leszek S. Czarnecki
Louisiana State University, USA
CPC power theory (tutorial) + "Why Fryze's approach failed" (TS 20)
Mon 14:00 + Thu 09:00
6 · Excursions & social events — when and how to register
The mechanism: every social event and both excursions are booked inside the online registration form at ichqp.ticket-web.site/2026 — you tick attendance for each. There is no separate excursion booking page. Places are allocated first-come, first-served.
If you've already registered but didn't tick them: contact the organisers directly and ask to be added —
registration@ichqp2026.org,
accessibility questions to registration-help@ichqp2026.org,
or phone +49 1551 1288184 (07:00–22:00 CEST). From Aug 31 onward, the information desk in the hotel Lobby can also fix it in person — but capacity may be gone by then.
Event
Date & times
Cost
How to get in
Verdict
Welcome Reception Nymphenbad, Dresdner Zwinger
Mon Aug 31 doors 18:30 / start 19:00 / end 22:00
Free (Reinhausen)
Tick in registration form. Accompanying persons: €110 at current rate.
€135 at current (post-Aug 15) rate. Was €95 early bird.
Advance reservation only, limited capacity, first-come-first-served. Lunch at Königstein + afternoon coffee at Bastei included.
Go if available
7 · Practical logistics
Registration & Information Desk — Lobby, Penck Hotel, Ostra-Allee 33. One counter, in the lobby, all four days. You can walk up without a prior booking: the official fee table still carries a live "last minute and on-site rate" column, and the ticket store is open and selling every tier right now.
Day
Desk open
Note
Mon 31 Aug
13:00 – 19:00
Opens one hour before tutorials start at 14:00. This is the only tight queue of the week.
Tue 1 Sep
07:30 – 18:00
Earliest opening — Opening Ceremony is 08:30 sharp.
Wed 2 Sep
08:30 – 18:00
Ask here for the gala boat platform assignment.
Thu 3 Sep
08:30 – 13:00
Closes at lunch — last chance for anything administrative.
Better than queueing: register online at ichqp.ticket-web.site/2026, which is live and taking last-minute bookings. The tutorial add-on is a separate line item and the store states "during checkout you will need to select the tutorials you would like to attend" — so doing it online locks your tutorial seats in before you arrive, instead of deciding at a counter with a queue behind you. Then the desk is just a badge pickup.
VenuePenck Hotel Dresden, Ostra-Allee 33, 01067 Dresden. Tram stop Kongresszentrum / Haus der Presse (lines 1, 6, 11) is a 2-min walk. S-Bahn Dresden Mitte is 5–7 min on foot.
Getting thereDresden Airport (DRS) is 9 km out — S-Bahn S2 to Dresden-Mitte, ~15 min, or a 15-min taxi. From Berlin BER: IC/EC/ICE to Dresden Hbf, 2–2.5 h, or Flixbus ~2 h.
Walking distancesHotel → Zwinger 750 m (10 min) · → Felix Restaurant 800 m (12 min) · → gala boat at Terrassenufer 1.2 km (20 min). The boat one is the only one that bites.
RoomsKunsthalle = opening, keynotes, panels, posters, art contest. A / B / Y = parallel sessions. D = Thursday only. C = Speaker Ready Room. Z + restaurant = lunch.
Wi-FiTwo free networks, no access code: Penck Hotel Guest and Penck Hotel Event. Just connect and accept the terms.
Conference appichqp2026.lineupr.com/ichqp-2026 — register with your ticket email, then "Add to Home Screen" for offline use. Required for the art contest vote.
BadgeWear it visibly. No badge = no admittance to sessions or social events. Collected with your conference materials at the Lobby desk.
FoodCoffee breaks and buffet lunches are free for all registered participants (Room Z + hotel restaurant). Lunch is 12:30–14:00 Tue/Wed, 12:30–13:30 Thu.
HotelConference rate at the Penck was €109 single / €134 double B&B — that rate expired June 30, 2026. Book direct: +49 351 4922-785 / reservierung@penckhotel.de, keyword ICHQP 2026.
Hotel-fraud warningThe organisers explicitly warn about scammers phoning/emailing attendees offering rooms for Aug 31–Sep 3 using the ICHQP logo. No legitimate ICHQP rep will ever ask for your card details by phone or email. Only one contingent exists, at the Penck.
HelpInfo desk in the Lobby, open daily. Phone +49 1551 1288184 (07:00–22:00), info@ichqp2026.org. Certificate of attendance is emailed after the conference.
ExtrasExhibition + Job Wall on the ground floor. Oral papers are 12 min + 3 min Q&A — a session is 5 papers, so leaving mid-session is disruptive. Plan at the session level, not the paper level.
8 · Copy-paste summary
⚡ ICHQP 2026 — Dresden, Germany (NOT Estonia)
Aug 31 – Sep 3, Penck Hotel Dresden. 22nd Intl Conference on Harmonics & Quality of Power — the only IEEE PES conference purely about Power Quality.
🔴 URGENT
• Registration is now at the last-minute rate: €900 regular / €480 student
• Both excursions had to be booked during online registration — call +49 1551 1288184 (07:00–22:00 CEST) or email registration@ichqp2026.org to get added
⏰ WHEN TO SHOW UP
Mon 31: 13:00 (desk opens, tutorials 14:00) — or 18:15 at the Zwinger for the reception
Tue 1: 08:00 — opening 08:30, all 4 keynotes 09:00–10:30. Be early.
Wed 2: 08:40 — vote in the art contest before 17:30, leave by 18:05 for the gala boat (20 min walk!)
Thu 3: 08:45 — closing 12:15, Meißen bus boards 13:30
Fri 4: 08:30 boarding for Saxon Switzerland
✅ GO TO
Mon: CPC power theory tutorial (Czarnecki) 14:00 + EV Charging metrology (van den Brom) 16:00
Mon eve: Welcome Reception at the Zwinger — best networking of the week
Tue: Opening + all 4 keynotes · Panel 2 (PQ data analysis) 11:00 · Panel 3 (AC/DC power electronics) 14:00 · TS2 EV charging & data centres 16:00
Wed: TS5 Grid-forming inverters 09:00 · TS11 LV distortion 11:00 · Poster session 14:00 · TS13 Sub-synchronous oscillations 16:00 · Gala dinner boat 18:30
Thu: TS17 Harmonic mitigation case studies 09:00 · TS22 Harmonic emission of other sources 11:00 · Meißen excursion 13:30
Fri: Saxon Switzerland (€135, if seats left)
❌ SKIP
Tutorial Track 3 (3h lock-in) · TS3, TS4, TS7, TS8, TS12, TS16, TS18, TS23 — narrow numerical-method sessions
🎤 KEYNOTES: Mark Halpin (Auburn, chairs IEC TC77/SC77A, ex-chair IEEE 519) · Sarah Rönnberg (Luleå, supraharmonics) · Zia Emin (EPRI, ex-chair CIGRE C4) · Marco Lindner (TransnetBW, IEEE TR77 task force)
📱 App: ichqp2026.lineupr.com/ichqp-2026 · WiFi: "Penck Hotel Guest", no code
Appendix · Power quality from scratch optional background
Open the primer — two mental models, the phenomena taxonomy, a 12-term glossary, the standards map, the 2–150 kHz gap, and the commercial landscape. ~20 min read. Collapsed by default; the conference plan above stands on its own.
Why this appendix exists. Optional background, parked out of the way of the conference plan. Written to be read on the plane, in order — not required to use the schedule above. If you absorb only the two mental models in A.1 and the vocabulary in A.3, you will follow essentially every talk at ICHQP. Everything after that is depth.
Anything below marked (contested) is genuinely argued about by the people in the room. Don't state it as settled fact at a coffee break.
A.1 · The two mental models that make the whole field click
Model 1 — Power quality is a compatibility problem, not a purity problem.
The instinct of every newcomer is that the goal is a perfect 50 Hz sine wave. It is not, and it never was. Perfect power is infinitely expensive and nobody needs it. The actual question the field asks is a three-way negotiation:
Level
The question it answers
Who it constrains
Emission limit
How much distortion is this one customer or device allowed to inject?
The connecting party — a factory, a wind farm, a charger, a TV
Compatibility level
How much distortion should we assume exists on the network, as a reference point for everyone?
Nobody directly. It's the agreed planning assumption that the other two are set against.
Immunity level
How much distortion must equipment survive without misbehaving?
The manufacturer of everything that plugs in
Set emission limits too loose and equipment breaks. Set them too tight and nothing can connect and the energy transition stalls. Set immunity too high and every appliance costs more. The entire field — every standard, every product, every argument you will hear this week — lives in the gap between those three numbers. Utilities lobby from the emission side. Manufacturers lobby from the immunity side. The standards bodies are the referee. That's the game.
Practical tell: when someone says a number like "8% THD", your first question should always be which of the three levels is that? — and the follow-up, at which point in the network? The same number means completely different things at a customer's terminals versus at the substation.
Model 2 — One trend is breaking the field: everything is becoming a power-electronic converter.
The 20th-century grid had a clean division of labour. Big spinning machines — coal, gas, hydro, nuclear — made the voltage. Their physical inertia and their windings defined the frequency and the impedance. Loads were mostly passive: motors, heaters, incandescent bulbs. They drew current in roughly the same shape as the voltage handed to them.
Both halves of that have now inverted:
Loads became switching converters. LED lighting, variable-frequency drives, EV chargers, data-centre power supplies, heat pumps, induction hobs, PV inverters in reverse. These don't draw a smooth sine of current — they chop it, at kilohertz, and the chopping shows up on the grid as distortion.
Sources became converters too. Solar and wind and batteries connect through inverters. An inverter has no physical inertia and no fixed impedance — it has a control algorithm, and its apparent impedance is whatever that firmware decides, differing by frequency and updated by software release.
That second point is the deep one, and it's the reason this conference exists in its current form. Grid stability used to be governed by physics you could measure once and write down. It is increasingly governed by proprietary control software from a dozen vendors, interacting in ways nobody simulated, in a grid where the stabilising spinning mass is being retired. When two vendors' control loops fight each other at 3.5 Hz across a national grid, that is a power quality event with no 20th-century analogue.
Run that lens over the 2026 programme and every hot topic falls out of it as a consequence: grid-forming inverters (can software fake inertia?), supraharmonics (the switching frequencies themselves, 2–150 kHz), sub-synchronous oscillations (control loops fighting), DC power quality (if everything's a converter anyway, why keep converting to AC?), EV charging and data centres (the two biggest new converter loads on earth). Not five topics. One topic, five faces.
A.2 · The phenomena — what actually goes wrong
The canonical taxonomy is IEEE Std 1159, Recommended Practice for Monitoring Electric Power Quality. Learn its rough shape and you'll never be lost about what kind of problem someone is describing. The organising axes are duration (microseconds to hours) and whether the waveform's shape or its magnitude is wrong.
Phenomenon
What it is
Timescale
Typical cause
What it costs you
Voltage sag / dip "sag" US, "dip" IEC
Voltage drops to roughly 10–90% of nominal, then recovers
Half a cycle to ~1 minute
A fault somewhere on the network, a big motor starting, a transformer energising
The single most expensive PQ phenomenon in industry. A 100 ms sag nobody notices in an office will drop a semiconductor fab, a plastics line or a paper mill and cost six figures in scrapped product and restart time.
Interruption
Voltage essentially gone (<10%)
Momentary to sustained (>1 min)
Protection operating, permanent fault
Obvious, and paradoxically less interesting — it's a reliability metric (SAIDI/SAIFI) that utilities already track and get regulated on. Sags are the ones that hide.
Harmonics
Current or voltage components at exact integer multiples of 50/60 Hz — the 3rd, 5th, 7th, 11th…
Steady state
Any non-linear load: rectifiers, drives, LED drivers, chargers
Extra heating in transformers, cables and motors; capacitor bank failures; nuisance breaker trips; overloaded neutral conductors. Slow, cumulative, easy to under-attribute.
Interharmonics
Components at non-integer multiples — 137 Hz on a 50 Hz grid
Steady state, often wandering
Anything with two unsynchronised frequencies inside it: variable-speed drives, wind turbines, cycloconverters, arc furnaces
Disproportionately nasty because they beat against the fundamental and produce visible flicker. Also much harder to measure than harmonics — you can't just bin them neatly into an FFT.
Supraharmonics 2–150 kHz
Emissions in the band above traditional harmonics and below where radio-frequency EMC rules begin
Steady state / bursty
The switching frequencies of modern converters, directly
The field's most-cited open hole — see A.5. Causes audible noise, interference with powerline communication and ripple control, and unexplained equipment misbehaviour. Barely regulated, inconsistently measured.
Flicker
Voltage amplitude modulating at a few Hz, which the human eye perceives as lights pulsing
Sub-second, continuous
Arc furnaces, welders, wind turbines, large cycling loads
Unusually, this one is defined by human perception — measured as Pst (short-term, 10 min) and Plt (long-term, 2 h), calibrated so Pst = 1 means the average person finds it just-annoying. LEDs behave completely differently from the incandescent lamps the metric was built on, which is an active problem — and a paper in TS 15.
Unbalance a.k.a. imbalance
The three phases aren't equal in magnitude or 120° apart
Overheats three-phase motors badly (a few % of unbalance causes a large % of extra rotor heating). Getting worse as single-phase EV charging and rooftop PV spread unevenly across streets.
Transients
Fast spikes. Impulsive (lightning, unidirectional) or oscillatory (capacitor switching, ringing)
Nanoseconds to milliseconds
Lightning, switching operations, ESD
Punches through insulation and semiconductors. Mostly an equipment-protection problem, and the most mature part of the field.
Frequency deviation
The grid isn't at 50.000 Hz
Seconds to minutes
Generation/load imbalance
Traditionally rock-solid in large interconnected grids and therefore boring. Becoming interesting again as inertia falls — a low-inertia grid changes frequency faster after a disturbance (high "RoCoF"), which is precisely why grid-forming inverters are the 2026 obsession.
Note on the sag/dip split: it's not just vocabulary. IEEE and IEC genuinely evolved separate terminologies, characterisations and limits for the same physics, and papers will silently assume one camp. If a number doesn't reconcile, check which tradition the author is in before you assume they're wrong.
A.3 · The vocabulary that will otherwise lose you
PCCPoint of Common Coupling. The electrical boundary where your installation meets everyone else's — usually the metering point. Almost every limit in every standard is defined at the PCC, not inside your factory. Inside your own fence you can distort as much as you like. This is the single most load-bearing three-letter acronym in the field.
THD vs TDDTotal Harmonic Distortion is harmonic content as a % of the fundamental — so a lightly loaded drive can show a terrifying 80% current THD while injecting almost nothing in absolute amps. Total Demand Distortion normalises to maximum demand current instead, which is why current limits are properly written in TDD. Confusing the two is the classic newcomer error, and a fast way to be wrong by an order of magnitude.
Emission vs immunityThe two halves of the field. Emission = what a device throws at the grid. Immunity = what a device can survive from the grid. Most academics work emission; most of the money is in immunity. Section 2.6 on why that matters commercially.
IBRInverter-Based Resource. Anything connecting through power electronics rather than a spinning shaft — solar, wind, batteries, HVDC. You'll hear "IBR-dominated grid" constantly; it means the region where the old assumptions stop holding.
Grid-following vs grid-formingA grid-following inverter measures the existing grid voltage and injects current in step with it — it needs someone else to define the voltage, so a grid of only these collapses. A grid-forming inverter behaves as a voltage source with its own internal reference, so it can hold up a grid by itself and synthesise inertia-like behaviour in software. Migrating the fleet from the first to the second is arguably the biggest open engineering programme in power systems. (contested: what exactly the requirements should be)
Harmonic impedanceHow much voltage distortion results from a given injected current, at each frequency — Z(f). It's the network's transfer function, and it decides whether an emission is harmless or catastrophic. It's also hard to measure, varies with switching state and time of day, and is increasingly set by inverter firmware rather than by copper and iron. Several sessions are effectively about this one quantity.
ResonanceCables are capacitive, transformers and lines are inductive; together they resonate at some frequency. Land a harmonic on that frequency and a modest current injection produces an enormous voltage. This is how a "small" harmonic problem destroys a capacitor bank. Adding cable (or solar, or filters) moves the resonance — sometimes onto a harmonic that was previously harmless.
Hosting capacityHow much additional distributed generation or new load a network section can absorb before some limit is breached — voltage, thermal, or distortion. It's the number that decides whether a connection request is approved. Deeply political, because the methodology determines who pays for reinforcement.
Pst / PltFlicker severity, short-term (10 min) and long-term (2 h). Pst = 1 is calibrated to the threshold of human irritation. One of very few engineering metrics defined by a psychophysical experiment rather than physics.
Class A / Class STwo performance classes for PQ instruments in IEC 61000-4-30. Class A is the rigorous one — two Class A instruments on the same signal must produce the same answer, which is what makes measurements admissible in a contractual dispute. Class S is a relaxed class for surveys and statistics. "Is it Class A?" is the correct first question to any instrument vendor on the exhibition floor.
PQDIF / COMTRADEThe interchange file formats — PQDIF (IEEE 1159.3) for power-quality data, COMTRADE (IEC 60255-24 / IEEE C37.111) for transient waveform records. Ask vendors whether they truly support them or merely export a CSV; data lock-in is a real and widely resented problem in this market.
NotchingA repetitive momentary collapse of the voltage waveform caused by commutation in line-commutated rectifiers — a visible notch every cycle. Distinctive-looking, well understood, and a nice thing to be able to recognise on a screenshot.
A.4 · The standards map — who owns which number
This is the part that looks like impenetrable alphabet soup and isn't. There are only four organisations and they have clearly separated jobs. Learn this and you'll follow any standards conversation at the conference.
Body
What it actually does
Output you'll hear cited
CIGRE — Study Committee C4 "Power system technical performance"
Not a standards body. Does the pre-normative engineering: working groups, field measurement campaigns, modelling methods, Technical Brochures. Characterises a phenomenon before anyone tries to put a number on it.
Technical Brochures ("TB 976", "TB 672"). Mark Halpin's CIGRE WG on emission limits is exactly this stage of the pipeline.
IEC — TC 77 and its subcommittee SC 77A EMC, low-frequency phenomena
Turns mature CIGRE work into normative text. SC 77A owns low-frequency EMC — nominally below 9 kHz — which is essentially all of classical power quality: harmonics, flicker, dips, unbalance, signalling.
The whole IEC 61000 series. Guglielmo Frigo convenes SC 77A WG 9 on measurement methods and chairs Panel 4.
CENELEC
Regionalises it for Europe, and turns "what may be emitted" into "what a customer is entitled to receive."
EN 50160 — the supply-voltage characteristics standard every European DSO is measured against.
IEEE — PES
Runs the parallel North American track. Overlapping subject matter, different terminology and different limit structure.
The one-line version: CIGRE characterises the phenomenon → IEC sets the number → CENELEC regionalises it for Europe → IEEE runs its own track for North America. When the ICHQP programme says this is "where standards get argued into shape," it means the first arrow.
The IEC 61000 numbering system, decoded. The middle digit is the whole trick:
61000-2-x — the environment.Compatibility levels: how much disturbance we agree to assume exists. (-2-2 public LV, -2-4 industrial, -2-12 public MV)
61000-3-x — limits. What a device or an installation may emit. (-3-2, -3-12 for equipment; the -3-6 and -3-7 Technical Reports for allocating a budget among large connecting customers)
61000-4-x — testing and measurement techniques. How you prove any of the above. (-4-7 harmonics, -4-15 flickermeter, -4-30 the PQ measurement bible)
Read left to right and it's the compatibility model from A.1, made operational: -2-x says what the environment tolerates → -3-6/-3-7 divides that budget among the big connecting customers → -3-2/-3-12 constrains what manufacturers ship → -4-x says how you measure to settle the argument.
The documents actually worth knowing by name
Standard
Current edition
What it does
The number to remember
IEEE Std 519
2022 (published Aug 2022; note it was promoted from "Recommended Practice" to "Standard")
Harmonic limits at the PCC. Structurally a two-sided contract: the utility is responsible for voltage distortion, the customer for current distortion.
At ≤1 kV: 8% voltage THD, 5% any individual harmonic. At 1–69 kV: 5% THD, 3% individual. Current limits are in TDD and scale with network strength (ISC/IL): from 5% TDD on a weak connection up to 20% on a very stiff one.
IEEE Std 1159
2019
The phenomena taxonomy in A.2 above, plus how to monitor and interpret. The shared vocabulary of the field.
Sag = 0.1–0.9 pu, half a cycle to 1 minute. Everything else hangs off that framing.
IEEE Std 1459
2025 (published May 2025 — genuinely new, supersedes the 2010 edition)
Defines P, Q, S, distortion power and effective apparent power when the waveform isn't a sinusoid. In effect: what a meter should compute.
This is the document being publicly torn apart in TS 20 on Thursday morning. A standard barely a year old already has a session's worth of critique aimed at it. That's the health of the argument, not a scandal.
IEEE Std 1453
2022
Flicker limits and measurement. Historically a straight adoption of the IEC flickermeter; now standalone but still normatively references IEC 61000-4-15 for the instrument.
Useful as the clearest example of IEEE and IEC not being rivals so much as differently-scoped.
EN 50160
2022, plus amendment A1:2025
What a European customer is entitled to receive — a description of the product, not an emission limit. The 2022 edition extended scope up to HV/EHV.
The 95%-of-week rule. Compliance is assessed over 1008 ten-minute intervals in a week and the limit must hold for 95% of them — not always. Headline values: voltage within ±10%, THD ≤8%, Plt ≤1, unbalance ≤2%.
IEC 61000-4-30
Edition 4.0, October 2025
The measurement bible. Defines methods precisely enough that two different instruments give the same answer on the same signal — which is the whole basis for PQ measurement being admissible in a commercial dispute.
Class A (rigorous, reproducible, contractual) vs Class S (surveys and statistics). Ed. 4.0 removed Class B and split the high-frequency annex into 2–9 kHz and 9–150 kHz. Aggregation chain: 10/12 cycles → 150/180 cycles → 10 min → 2 h.
IEC 61000-4-7
Ed. 2.1 (2002 + A1:2008)
How harmonics and interharmonics are actually computed.
200 ms windows (10 cycles at 50 Hz), grouped into 200 Hz bands, up to 9 kHz. That 9 kHz ceiling is where the supraharmonic problem in 2.5 begins.
IEC 61000-3-2 / -3-12
-3-2: 2018 + A1:2020 + A2:2024 · -3-12: Ed. 2.1
Emission limits for individual equipment on public LV. This is what makes your laptop charger legal.
Split at 16 A per phase (-3-2 below, -3-12 from 16 to 75 A). -3-2 uses equipment classes A–D; -3-12 scales the allowance by network short-circuit ratio.
IEC TR 61000-3-6 / -3-7
Both Ed. 2.0, 2008 — and both Technical Reports, not standards
Allocation. How a network operator divides a finite distortion budget among the large customers connecting to MV/HV. -3-6 for harmonics, -3-7 for flicker.
Note the age: 2008, i.e. pre-dating the entire inverter-dominated grid. Mark Halpin convenes the CIGRE group revising exactly this. That's why Panel 1 and TS 10 matter more than their titles suggest.
Honesty note on the numbers above: the IEEE 519-2022 tables were verified against a redline review reproducing the published tables. The EN 50160 headline values are the long-standing ones and are corroborated for the current edition by secondary sources, but I did not obtain the paid EN 50160:2022+A1:2025 text to check every cell. Treat the EN 50160 figures as "right to one significant figure and right in spirit," and don't quote them into a contract without the actual document. Same caution on the IEEE 1159 duration/magnitude cells in 2.2.
A.5 · The field's biggest open hole: 2–150 kHz
If you learn one "unsolved problem" well enough to discuss it, make it this one. It comes up in the keynotes, in Panel 4, in at least three technical sessions and on the exhibition floor, and understanding it makes you legible as someone who's actually paying attention.
How the gap got there. Two communities regulated the frequency spectrum from opposite ends and didn't meet in the middle:
Below ~2 kHz — the power engineers. Well covered: IEEE 519, EN 50160, IEC 61000-2-x and -3-x. Mature, enforced, litigated.
Above 150 kHz — the radio and broadcast community, protecting their spectrum via the CISPR standards. Strict, old, well-policed.
2 kHz to 150 kHz — nobody's. A regulatory no-man's-land.
Then modern power electronics moved in. This band is exactly where converters switch. And here's the genuinely perverse bit, documented in the literature: because the <2 kHz limits were enforced, product designers had an incentive to meet them by pushing emissions up into the unregulated band instead. The regulation didn't remove the energy; it relocated it somewhere nobody was measuring.
What it breaks in practice: EV chargers malfunctioning near each other, interference with utility ripple-control and powerline-communication signalling, audible noise from transformers and appliances, LED drivers behaving strangely, and a general category of "unexplained equipment misbehaviour" that gets written off because nobody's instrument can see the cause.
Why it stays unsolved — four distinct holes, not one:
No compatibility levels. Nobody has agreed how much of this the environment should be assumed to contain.
No mandatory emission limits. What exists is provisional (CISPR 15, for lighting) or merely recommended (IEC TS 62578, for active infeed converters). There's an immunity standard — IEC 61000-4-19 — but immunity without an emission limit is half a compatibility model.
Two incompatible measurement methods. IEC 61000-4-7 covers 2–9 kHz one way; 61000-4-30's annex covers 9–150 kHz another way, with different filtering and grouping. Results across the full range aren't directly comparable — and until 2025 the high-frequency annex was informative, i.e. not binding.
Impedance isn't specified. A voltage-based measurement is only reproducible if you know the grid impedance at that frequency, and the measurement standards don't tell you how to establish it. This is why you'll hear "we have no standardised impedance measurement above 9 kHz" repeated all week like a refrain — it's the blocker underneath the blocker.
Why a PM should care more than an engineer. A standards vacuum with real customer pain is the most valuable position in an instrumentation market. Most installed monitors physically cannot see this band — not just software, but sampling rate and, critically, the current and voltage transducers in front of the ADC. When the measurement method converges, there is a hardware replacement cycle waiting behind it. And the vendor whose method is credible, repeatable and public when that happens tends to become the reference. Watch which exhibitors can answer question 2 from the exhibition checklist without flinching.
A.6 · The economics — where the money actually is
The technical field and the commercial field don't have the same shape, and the gap between them is where a PM earns their keep. Four things are worth internalising before you land.
(a) Voltage sags are the expensive phenomenon; harmonics are the famous one.
The conference is named after harmonics and the majority of the papers are about them. But harmonics mostly cost you slow, diffuse, hard-to-attribute losses — extra heating, shortened equipment life, the occasional capacitor bank. Voltage sags cost money in a single visible event: a 100-millisecond dip nobody notices in an office drops a semiconductor fab, a plastics line or a paper mill and destroys a batch. Note the mismatch — academic attention is on harmonics, industrial willingness-to-pay is on sags and interruptions. Mismatches like that are where products come from.
(b) The industry's headline cost figures are alarmingly old — and that is itself a finding.
Nearly every PQ pitch deck you will ever see rests on two studies:
EPRI/Primen (2001) — power disturbances cost the US economy over $119 billion a year, of which roughly $15–24 billion is power-quality rather than outright outages. Survey-based, self-reported, 25 years old.
Leonardo Energy / European Copper Institute (2008) — poor power quality costs EU business over €150 billion a year, about 90% of it industrial, with voltage dips and short interruptions responsible for more than half of all losses. Based on 62 participants across 8 countries, extrapolated to a continent.
Both are weak evidence carrying enormous commercial weight. There is no modern, credible, bottom-up cost-of-power-quality study. If you want a conversation-starter that makes senior people in that building lean in, "why is the economic case for this entire industry resting on a 2001 survey?" is a very good one — and the freshest usable adjacent datapoint, the Uptime Institute's 2025 outage analysis, is worth having ready: power causes about 45% of impactful data-centre outages, 57% of recent major outages cost over $100k, and one in five cost over $1M.
(c) "The power quality market" is three different businesses wearing one label.
Business
What's sold
Shape
Who plays
Mitigation iron
Passive filters, active harmonic filters, STATCOM/SVC, dynamic voltage restorers, UPS
Low volume, very high value, project-and-EPC sales, long cycles
Different buyers, different channels, wildly different margins. Reasoning about "the PQ market" as one thing is the fastest way to be wrong. Also worth knowing:OMICRON, who you'd assume is a monitor vendor, isn't — they sell the test equipment that verifies everyone else's Class A claim. They're the referee, not a player, which is a nice position and worth understanding before you talk to their booth.
(d) Market sizing here is soft — and the spread is the real signal.
Published estimates for "power quality equipment" put the 2024 base anywhere from $20B to $42B — a 2× spread on the same named market, because the definitional boundary (does UPS count? surge protection? capacitors?) is doing all the work. Consensus growth clusters around 5.4–6.8% CAGR. The tightest and most credible slice is active harmonic filters at roughly $0.7–1.2B growing ~8%, where three independent firms agree within about ±25% on base and 0.4 points on growth rate — unusually good for this genre. Treat everything else as directional. And be suspicious of the standard TAM argument that sets a €150B cost-of-poor-PQ against a ~$30B equipment market: both numbers are weak, so their ratio is weaker still.
The category is consolidating right now, which is useful context for corridor conversations: Powerside acquired Electrotek — and with it PQView, the de-facto utility analytics platform — from GMC Instruments in March 2025, and private equity took a majority stake in A. Eberle in April 2026. Expect roll-ups pairing instruments with analytics.
What practitioners say is missing — your product-gap shortlist
Take these to the poster hall and the exhibition and test them. They're synthesised from the literature and from practitioner complaints, not from vendor marketing, and every one is a question you can ask out loud:
The last mile from waveform to decision. The instruments are good; the software that turns a capture into a report someone will act on is the consistent complaint. "It takes hours to wade through the software" is a real, repeated user sentiment about market-leading hardware.
Data interoperability is nominally solved and actually isn't. PQDIF (IEEE 1159.3) exists, but it's a binary format so flexible that whether a given tool can read a given file is a genuine question. Large utilities run per-country systems that don't talk to each other. A modern, streamable, semantically-typed PQ data model is an unclaimed position.
Latency. The dominant utility analytics platform polls devices roughly once a day by design. For sag-sensitive loads and for interconnection compliance, day-late is the wrong answer.
Event classification isn't actually automated. A large research literature exists and the reviews are blunt: there's a persistent gap between published detection methods and real deployment, no labelled datasets at scale, and no open benchmark database. Whoever builds the labelled corpus plausibly owns the category.
Monitor cost caps deployment density — which is why there's an entire sub-field about optimal sparse placement. Meanwhile every demand driver (rooftop solar, EV charging, heat pumps) is pushing the problem down to LV feeders where you'd need 100–1000× more measurement points at a price current instruments can't reach.
Attribution is the feature customers actually want. "A sag occurred" is not the commercial question. "Was it upstream or downstream — i.e. who pays?" is. Schneider patents and markets disturbance direction detection for precisely this reason, and extending it to multi-site triangulation across a feeder is largely unserved.
Why the demand curve is bending right now — the five forces to have at your fingertips.
Data centres, in both directions. US data-centre consumption went from 58 TWh in 2014 to 176 TWh in 2023, with projections of 325–580 TWh by 2028. Inbound, AI clusters are the most sag-sensitive load class ever built at that scale. Outbound — and this is the new part — multi-hundred-megawatt loads with second-scale ramp variability have become a grid problem, and interconnection rules are starting to specify harmonic emission limits and validated load models for large loads. That turns PQ measurement from a nice-to-have into an interconnection deliverable with a named budget holder.
EV charging. Numerous, small, built by non-utility developers who often can't energise at requested capacity without a harmonic study and a filter. The segment most likely to want a cheap, standardised, self-service product — the exact opposite of the traditional utility sale.
Rooftop solar. Reverse power flow, overvoltage causing inverters to curtail themselves, unbalance from single-phase installs, resonance at the PCC. Fundamentally a monitoring-density and attribution problem, not a mitigation-hardware one.
Grid-forming requirements. ENTSO-E published its Phase II grid-forming technical report in November 2025 with a final report due Q1 2026, and NERC is running a parallel track. Every requirement in those specs needs high-bandwidth, time-synchronised instrumentation to prove at commissioning. A brand-new compliance-testing category, arriving on a regulatory clock. This is why TS 5 and Panel 3 are worth your Wednesday morning.
Supraharmonics — see A.5. A hardware replacement cycle waiting on standards convergence.
A.7 · Your learning path for the week
Read the schedule in section 4 for the picks. Read this for the arc — what each day is supposed to install in your head:
Day
What you're there to learn
The one thing to walk out with
Mon Tutorials
Foundations, taught deliberately. Power definitions under distortion (CPC), then measurement and verification of a real modern load (EV charging).
Why "power factor" stops being well-defined once the waveform isn't sinusoidal — and that the field has not agreed on a replacement.
Tue Keynotes + panels
The state of the field from the people who set it, then the two live arguments: how compliance actually works in the field (Panel 1) and what converters are doing to AC and DC networks (Panel 3).
A map of who owns which decision. After Tuesday you should be able to name the body responsible for any given limit.
Wed Sessions + posters
Morning: the frontier (grid-forming, LV distortion). Afternoon: the poster hall, which is the day's real event. Late: what actually breaks (TS 15).
Ten conversations with people who will answer "what would have made this easier?" honestly. This is your product-research day — protect it.
Thu Case studies
Engineering, not theory: real installations diagnosed and fixed (TS 17), then the weird failure modes nobody warns you about (TS 22).
A concrete sense of what a PQ engagement looks like end to end — symptom, measurement, diagnosis, mitigation, verification. That shape is the product.
Three habits that will double what you retain.
Keep a running "words I nodded at" list. Every time you let a term pass without really knowing it, write it down. Look up five each evening. In a dense specialist field this beats trying to follow everything in real time — and the list itself tells you where the jargon walls are, which is useful product information on its own.
Ask the same question of many people. Pick two — I'd suggest "what's the most common power quality problem you see that people misdiagnose?" and "what would you measure if measuring were free?" — and ask thirty people. The distribution of answers is worth more than any single expert opinion, and it's the kind of thing you can only collect in a building like this.
Write it up Thursday night, not next week. Conference notes decay faster than almost any other kind. An hour on the train back is worth a day a fortnight later.
A.8 · If you want to go deeper afterwards
Math Bollen & Irene Gu, Signal Processing of Power Quality Disturbances — and Bollen's Understanding Power Quality Problems: Voltage Sags and Interruptions. Bollen is the field's canonical author and he is in the building — he co-authors the Monday GIC tutorial and three Wednesday posters. Reading even a chapter before you go makes meeting him worthwhile.
Roger Dugan et al., Electrical Power Systems Quality — the standard practitioner textbook; the one most people in the room learned from.
IEEE Std 1159 for the phenomena taxonomy and IEC 61000-4-30 for how to measure it — read the scope sections at minimum. These two documents are the shared vocabulary of everyone at the conference.
EN 50160 if you want the European supply-contract view — it's short, readable, and it's what a European DSO is actually held to.
The ICHQP 2026 proceedings themselves, once they're on IEEE Xplore. You'll have heard the talks, which makes the papers far faster to read.
Standards designations and edition years were checked against issuing-body pages; where a paid document couldn't be obtained, that's flagged in the text rather than papered over.
Last updated: 2026-09-14, 16:00 UTC · v6 — the page is now the conference plan and nothing else. The power-quality primer moved out of the main flow into a collapsed appendix at the bottom — it's optional background, not the point. The top of the page is now a dated "today's decisions" block instead of a generic warning.
What changed in v6 (post-conference): TU Dresden published the tutorial slides. All eight PDFs across all three tracks are now linked from both the Monday schedule and the planner, including the tracks that were not attended. Note that the share covers tutorials only — no keynote, panel or technical-session decks are in it. The green badges remain pre-conference recommendations, not an attendance record.
What changed in v5: Added the registration desk location and its opening hours for all four days, and confirmed against the live ticket store that walk-up and last-minute online registration are both still open.
What changed in v4: Registration terms re-fetched from the official fee page. Tutorial rules are now quoted, not guessed — one fee covers up to two consecutive 1.5-hour tutorials, tracks may be mixed, and the tutorials must be named on the form. Added the IEEE / IEEE-PES member and student rate tiers, and the €25 student tutorial fee, to the planner.
What changed in v3: Primer demoted to a collapsible appendix · new Monday decision list at the top, ordered by when each choice expires · sections renumbered.
What changed in v2 (kept): Monday's tutorials went from optional to the most important block of the week · the exhibition floor and the Job Wall became scheduled agenda items with a scripted question list · the poster session got specific stops and a working method · TS 15 (equipment sensitivity) was promoted over TS 13 because the immunity side is the half that connects PQ to money · Panel 1 was upgraded to an equal pick alongside Panel 2 · and the CPC tutorial now carries a caveat that it's one contested framework, not the consensus.
Confidence notes: All times, rooms, chairs, fees and contact details come from the official booklet revised 27 Aug 2026 and the live site — solid. Standards designations and edition years in the appendix were verified against issuing-body pages; the EN 50160 and IEEE 1159 numeric tables are the long-standing published values but were not checked cell-by-cell against the current paid editions, and are flagged as such in the text. Market-size figures are analyst estimates and are soft by nature — the spread is discussed rather than hidden. The green/amber/grey recommendations remain my judgement. Fees, tutorial rules and inclusions were re-verified against the official registration page on 31 Aug 2026. Excursion availability remains unverified — nobody has phoned the desk. Whether you're registered at all is something only you can confirm.
Built by Chui 🐆 for Sahir. Still outstanding: Estonia vs Dresden, and whether you're registered.